D6 Data

Dimensions D6T

Dimension (Unit:mm)

Dimensions D6X

Dimension (Unit:mm)

Dimensions D6WX

Dimension (Unit:mm)

Dimensions D6S

Dimension (Unit:mm)

Ratings

1)
WEEE
(RoHS)
Part
Number
Rated
Functioning
Temperature
Tf
(℃)
Operating
Temperature
(℃)
Maximum
Temperature
Limit
Tm
(℃)
Rated
Current / Voltage
(DC)
Heater Resistance
D6T-S1






139







136±3







180




12A / 32V
50.0±20%
D6T-215-S1 21.5±20%
D6T-050-S1 5.0±20%
D6X 50.0±20%
D6X-215 21.5±20%
D6X-050 5.0±20%
D6WX
15A / 32V
50.0±20%
D6WX-215 21.5±20%
D6WX-050 5.0±20%
D6SA2-12
-

-

-

12A/36V
2.15±20%
D6SA3-12 7.3±20%
D6SA4-12 14.7±20%

1) No use the hazardous substance prescribed by WEEE and RoHS. All products do not use SVHC prescribed by REACH (174 substances, 7 July 2017).

Safety Standards

Part
Number
UL/cUL
Made in Thailand
VDE/TÜV
Made in Thailand
D6T-S1






E71747




VDE
677802
-1171
-0008
D6T-215-S1
D6T-050-S1
D6X
D6X-215
D6X-050
D6WX
D6WX-215
D6WX-050
D6SA2-12

E357922

TÜV
J50247451
D6SA3-12
D6SA4-12


SCHOTT uses Cookies on this Website to enhance the user experience and provide the best possible Service. By continuing to browse the Website, you consent to our use of Cookies.